Rebar sizes in plain English

Rebar is sized in eighths of an inch. A #3 bar is 3/8 inch, a #4 is 1/2 inch, a #5 is 5/8 inch. Residential flatwork uses #3 and #4 almost exclusively; #5 shows up in footings and structural walls.

Bar sizeDiameterWeight per ftTypical residential use
#30.375 in0.376 lbPatios, sidewalks, thin slabs
#40.500 in0.668 lbDriveways, garage slabs, footings
#50.625 in1.043 lbFoundation walls, heavy footings
#60.750 in1.502 lbStructural columns and grade beams

Standard spacing by application

Spacing is specified as bars each way on a grid. Common residential specs:

ApplicationBar sizeSpacingSlab thickness
Sidewalk / patio#318 in OC each way4 in
Driveway (cars)#418 in OC each way4–5 in
Driveway (RV / truck)#412 in OC each way6 in
Garage slab#416 in OC each way4–6 in
Strip footing#42 bars continuous8–12 in deep
Always defer to a local engineer's spec or the permit drawing when one exists.

Cover and position matter more than quantity

Steel only works if it sits in the right part of the slab. For a slab on grade, rebar belongs in the middle third, or one-third up from the bottom for slabs in bending. Minimum cover is 3 inches when concrete is cast against earth and 1.5 inches for formed surfaces exposed to weather.

Rebar laid on the ground and 'pulled up' during the pour never ends up where it should. Use chairs or dobies every 3–4 feet in both directions.

Rebar grid on chairs showing consistent spacing and cover over gravel base
Chairs every 3–4 feet keep the grid at mid-depth while the crew walks the pour.

Step-by-step

  1. 1

    Calculate bars in each direction

    Bars = (slab dimension in inches ÷ spacing) + 1. For a 20 x 24 ft driveway at 18 inches on-center: across the 20 ft (240 in) direction, 240 ÷ 18 + 1 = 14 bars, each 24 ft long. Across the 24 ft (288 in) direction, 288 ÷ 18 + 1 = 17 bars, each 20 ft long.

  2. 2

    Subtract the edge cover

    Bars stop 3 inches short of each edge, so a 24 ft bar is really 23.5 ft. This does not change the count, but it does change how you cut stock lengths.

  3. 3

    Convert to purchased stock lengths

    Rebar is sold in 10 and 20 ft lengths. 14 bars x 23.5 ft = 329 linear ft; 17 bars x 19.5 ft = 332 linear ft. Total 661 linear ft, or 34 pieces of 20 ft #4 rebar before splices.

  4. 4

    Add lap splices where bars join

    Where two bars overlap, the lap must be at least 40 bar diameters — 20 inches for #4 bar, 15 inches for #3, and never less than 12 inches. Tie every lap with wire in at least two places. On our driveway, the 24 ft runs need one splice each: 14 splices x 20 in = 23 extra linear feet.

  5. 5

    Add the grid ties

    Tie every intersection on the perimeter and every second or third intersection in the field. A 14 x 17 grid has 238 intersections; tying two-thirds of them uses about 160 ties, or roughly one 3.5 lb roll of 16-gauge tie wire.

  6. 6

    Set chairs and re-check before the pour

    Place chairs on a 3–4 ft grid, then walk the slab and confirm nothing has sagged. Take a photo of the finished grid — many inspectors accept photo evidence, and it documents the work if you ever sell the house.

  7. 7

    Plan the control joints around the steel

    Saw-cut or tool control joints within 6–18 hours of the pour, at intervals of 24–30 times the slab thickness (8–12 ft for a 4-inch slab), cutting one-quarter of the depth. Rebar continues through control joints; only expansion joints break the steel.